Y-Axis Microswitches Replacement

Model [X] AON-M2 [X] AON-M2 2020
Category [ ] Preventive [X] Corrective [ ] Troubleshooting

Summary

This procedure gives the instructions on how to replace the two Y-axis microswitches in the machine.

Tools

Qty Description Specification
1 Wrench 1/4 in.
1 Hex Key 5/64 in.
1 Tape Non-Glossy
1 Marker Fine Tip (preferred)

Parts Information

Qty Part Number Description
2 EL-END-SWITCH End Stop Microswitch
4 HW-WASH-SLEEVE-PTFE-#2 No. 2 Teflon™ Sleeve Washer
4 HW-CD-NUT-2/56-SS No. 2 Crush Nut

Personal Protective Equipment

Qty Description Specification
1 Safety Glasses N/A

Prepare the Machine

  1. Home XYZ.
  2. Lower the Z-axis by 200 mm.
  3. Move the Y-axis 200 mm from the home position.
  4. Push the E-stop button.
  5. Wait until the build chamber, build plate and hot ends are at room temperature.

Remove the Microswitches

Illustration Example

  1. With the tape and the marker, tag the two wires (1) that connect to the microswitch (2).
  2. Disconnect the two wires from the microswitch. Illustration Example
  3. With the 5/64 in. hex key and the 1/4 in. wrench, remove the following components from the machine:
    • the two screws (3)
    • the two Teflon™ sleeve washers (5)
    • the two washers (6)
    • the two crush nuts (4).
  4. Discard the two Teflon™ sleeve washers and the two crush nuts.
  5. Remove the microswitch from the machine.
  6. If required, do steps 1 to 5 with the other Y-axis microswitch.

Install the Microswitches

  1. Put the microswitch (2) in position in the machine.

    Do not tighten the screws too much. The microswitch is fragile. Failure to do so can damage the components.

  2. With the 5/64 in. hex key and the 1/4 in. wrench, install the following components in the machine:
    • the two screws (3)
    • the two new Teflon™ sleeve washers (5)
    • the two washers (6)
    • the two new crush nuts (4).
  3. Connect the two wires (1) to the microswitch (2).

    Use the tags identified during the removal to connect the wires to the proper terminals on the microswitch.

  4. If required, do steps 1 to 3 with the other Y-axis microswitch.

Test and Return to Service

  1. Release the E-stop button.
  2. Home XYZ.
  3. Make sure that the microswitches operate correctly. Refer to the microswitches inspection.

Last modified: June 28, 2021