Model | [•] AON M2+ (CE) | [•] AON M2+ (R-NZ) | [•] AON M2+ | [•] AON-M2 2020 | [•] AON-M2 |
Category | [•] Preventive | [ ] Corrective | |||
Frequency | [•] Daily | [ ] Weekly | [ ] Monthly | [ ] Yearly | [ ] As Needed |
The procedure that follows gives instructions on how to clean the build platform and build chamber.
Estimated time: 30 minutes
Qty | Description | Specification |
---|---|---|
1 | Broom and Pan | N/A |
1 | Vacuum Cleaner | Optional |
A/R | Rags | Lint-free |
A/R | Isopropyl Alcohol | 99% |
None required.
Qty | Description | Minimum Specification |
---|---|---|
1 | Safety Eyewear | ANSI/ISEA Z87.1 |
A/R | Nitrile Gloves | ISO 2859-1 or ASTM D6319 |
Make sure that there are no prints on the build surface. Remove print(s) before the procedure that follows is started. Failure to do so can cause a collision and cause damage to the machine component(s).
Wait until all machine components are at room temperature before you continue. Some machine components can be hot if the machine was recently used. Failure to do so can cause injuries.
Polymer material is purged from the nozzle(s) after each automatic tool change when dual extrusion prints are in progress. The toolhead(s) cleans the nozzle(s) on the wiper brush(es) and the wiper blade(s) and the polymer material falls onto the build platform and at the bottom of the build chamber.
• To inspect the wiper brush and/or wiper blade, refer to Inspect Wiper Brushes and Wiper Blades.
• To replace the wiper brush and/or wiper blade, refer to Replace Wiper Brushes and Wiper Blades.