Replace Extruders
|
|
|
|
|
|
Model |
[ ] AON M2+ (CE) |
[ ] AON M2+ (R-NZ) |
[ ] AON M2+ |
[•] AON-M2 2020 |
[•] AON-M2 |
Category |
[ ] Preventive |
[•] Corrective |
|
|
|
Summary
The procedure that follows gives the instructions on how to replace the two extruders.
Estimated time: 60 minutes
Qty |
Description |
Specification |
1 |
Hex Key |
2.5 mm |
1 |
Hex Key |
2 mm |
Qty |
Part Number |
Description |
1 |
A-0503-001 |
Extruder Assembly - Left |
1 |
A-0503-002 |
Extruder Assembly - Right |
1 |
M2-SUB-EL-MTR-EXT-HT-L |
Extruder Assembly - Left (AON-M2) |
1 |
M2-SUB-EL-MTR-EXT-HT-R |
Extruder Assembly - Right (AON-M2) |
Reach out to our Customer Success team at help@aon3d.com for genuine AON3D replacement part(s) inquiries.
Personal Protective Equipment
Qty |
Description |
Minimum Specification |
1 |
Safety Eyewear |
ANSI/ISEA Z87.1 |
A/R |
Nitrile Gloves |
ISO 2859-1 or ASTM D6319 |
Prepare the Machine
Make sure that there are no prints on the build surface. Remove print(s) before the procedure that follows is started. Failure to do so can cause a collision which can cause damage to the machine component(s).
- Unload the filament from the extruder. Refer to Replace Filament.
- Home XYZ.
- Lower the Z-axis by 300 mm.
- Open the build chamber door.
- Push the E-stop button.
- Turn the power OFF with the ON/OFF switch found on the rear panel of the machine.
- Disconnect the main power cord from the receptacle.
- Wait until the build chamber, build platform and hot ends are at room temperature.
Remove the Extruders
Remove the Probe Assembly
Wait until all the machine components are at room temperature before you continue. Some machine components can be hot if the machine was recently used. Failure to do so can cause injuries.
- Remove the probe assembly. Refer to Replace Probe Assemblies.
Remove the Extruder
- Use the 2.5 mm hex key to remove the extruder top screw (1) and the extruder bottom screw (2).
- Use the 2 mm hex key to remove the two screws (3) on the front cover found on the extruder assembly.
- Carefully remove the extruder assembly from the toolhead plate.
Do not disconnect the cooling loop and electrical cable that are attached to the extruder assembly.
Install the Extruders
If the Extruder pro are installed, make sure to change the extruder motor step-per-mm value. Refer to the Install the Extruder Pro procedure.
Install the New Extruder
- Position the new extruder assembly onto the extruder motor.
- Manually install the two front cover screws (3) through the front cover and into the extruder motor. Do not tighten the two front screws (3) at this point in time.
- Position the extruder assembly onto the toolhead plate.
- Manually install the extruder top screw (1) and the extruder bottom screw (2).
- Use the 2.5 mm hex key to tighten the extruder top screw (1) and the extruder bottom screw (2).
- Use the 2 mm hex key to tighten the two front screws (3).
- Make sure that the screws that follow are tight:
- One extruder top screw (1)
- One extruder bottom screw (2)
- Two front cover screws (3).
Install the Probe Assembly
- Install the probe assembly. Refer to Replace Probe Assemblies.
Test and Return to Service
- Make sure that you remove all the tools from the build chamber.
- Close the build chamber door.
- Connect the main power cord to the receptacle.
- Turn the power ON with the ON/OFF switch found on the rear panel of the machine.
- Release the E-stop button.
- Home XYZ.