Inspect Z-Axis Lubrication (M2+)

Model [] AON M2+ (CE) [] AON M2+ (R-NZ) [] AON M2+ [ ] AON-M2 2020 [ ] AON-M2
Category [] Preventive [ ] Corrective
Frequency [ ] Daily [] Weekly [ ] Monthly [ ] Yearly [ ] As Needed

For instructions on how to inspect the AON-M2 and AON-M2 2020 Z-axis linear components, refer to the Inspect Z-Axis Lubrication procedure.

Summary

The procedure that follows gives instructions on how to make sure that the Z-axis linear components are correctly lubricated.

Estimated time: 15 minutes

Tools

None required.

Parts Information

None required.

Personal Protective Equipment

Qty Description Minimum Specification
1 Safety Eyewear ANSI/ISEA Z87.1
A/R Nitrile Gloves ISO 2859-1 or ASTM D6319

Prepare the Machine

Make sure that there are no prints on the build surface. Remove print(s) before the procedure that follows is started. Failure to do so can cause a collision and cause damage to the machine component(s).

  1. Home XYZ.
  2. Open the build chamber door.
  3. Push the E-stop button.
  4. Wait until the build chamber, build platform and hot ends are at room temperature.

Inspect Z-Axis Linear Components

Wait until all machine components are at room temperature before you continue. Some machine components can be hot if the machine was recently used. Failure to do so can cause injuries.

Inspect Z-Axis Linear Components Inspect Z-Axis Linear Components

  1. Make sure that the two Z-axis lead screws (1) and the two lead nuts (2) are not dry or have unwanted contamination.
  2. Close the build chamber door.
  3. Release the E-stop button.
  4. Do the steps that follow and listen for loud and/or unusual noises:
    1. Home XYZ.
    2. Lower the Z-axis by 450 mm.
    3. Home XYZ.
  5. If vibrations and/or unusual noises were heard in the step 4, refer to Clean and Lubricate Z-Axis (M2+).

Test and Return to Service

  1. Home XYZ.

Last modified: March 7, 2024